Based on the new coil winding calculations, I am going to slim down the coils to hit a target of ~200 wraps. Now the coils appear to be proportioned like the coils on the WB6. Here is what the adjustment looks like:
- coil_length: 116,309.299858263 mm
- outside_radius: 242.487113059643 mm
- wraps: 225
- torus_midplane_radius: 192.693468865964 mm
- donut_exterier_radius: 107.8 mm
- torus_radius: 84.0 mm
- donut_hole_radius: 60.2 mm
- torus_tube_radius: 23.8 mm
- torus_tube_hollow_radius: 18.802 mm
- joint_radius: 16.66 mm
- joint_negative_radius: 5.831 mm
- torus_tube_wall_thickness: 4.998 mm
Next we will calculate Forces_between_two_magnetic_dipoles, and Power_dissipation of the coils in the form of heat. This will give us some idea of the tensile strength and temperature envelope of the device.